PM10 Ultrasonic Thickness Measurement Workstation
Probe frequency: 1 MHz to 75 MHz
Digital frequency: 500 MHz / 12 bits
Measurement range: For steel, the upper limit is greater than 10 mm (window mode), depending on the probe, workpiece condition, and instrument settings.
The lower limit in steel is 0.05 mm.
Application fields: Precision manufacturing, aerospace, defense industry, automotive manufacturing, special equipment, petrochemicals, and more.
Application areas: Turbine blades, interactive template inspection, ship inspection, material corrosion scanning and imaging, multilayer coating thickness measurement, multi‑channel measurement, conventional material thickness measurement, and thickness measurement of attenuating materials such as cast iron and rubber.
Key words:
Product Classification:
- Product Features
- Applications
- Technical Parameter
- Standard Configuration
-
High resolution
In MEV mode, it delivers ultra-high resolution down to 0.0001, with highly stable and repeatable readings, truly achieving micron-level precision in thickness measurement.


Multi-layer thickness measurement
It can simultaneously measure and display the thickness of up to five independent layers, with each layer featuring 26 individual parameters, and also supports dual-layer, oxide layer, and dual-measurement modes.
Interactive System
Import measurement images and perform operations such as marking, moving, modifying, and resetting measurement points. Record the workflow in a visualized manner, and store the data so that you can open it to view measurement trend charts and bar graphs.


Four channels
Four channels perform measurements simultaneously, with each channel's A-scan displayed in real time. The parameters for each channel are independent, effectively enhancing detection efficiency.
Ultra-large capacity storage
512GB of ultra-large memory allows you to store A-scan and B-scan parameter configurations, customize storage names, and tag important files.


Multiple probe compatibilities
Compatible with a variety of probes, specially designed to tackle diverse thickness measurement challenges.
-
· Multi-layer measurement function
Thickness measurement of laminated windscreen glass: Displays the thickness of each layer simultaneously.
· High‑precision thickness measurement
Real resolution test blocks with a 1 µm difference
· Thin-walled pipe thickness measurement
Using a probe holder allows for better measurement of small tubes.
· Corrosion scanning function
According to the B-scan from the encoder, defects can be detected.
· High‑frequency probe thickness measurement
It is compatible with high-frequency probes up to 75 MHz and can simultaneously measure the thickness of multiple coating layers.
· Penetration coating function
Can penetrate a 100mm coating to measure the substrate.
-
PM10- Technical Parameters
Measurement Principle P-E (Pulse-Echo Method), 1-E (Interface Wave-Echo Method), E-E (Echo-Echo Method), MEV (Multiple Echo Verification Method) Probe Type Supports delay line probes, contact probes, protective film probes, pencil probes, and immersion probes. Calibration Method Zero probe calibration, zero coating calibration, sound velocity calibration, single-point calibration, two-point calibration, set sound velocity, material sound velocity table Upper measurement limit in steel Greater than 10 m (window mode), depending on the probe, workpiece condition, and instrument settings. Measurement lower limit in steel 0.05 mm (50 MHz probe), 0.10 mm (20 MHz probe), 0.13 mm (15 MHz probe) Material sound velocity range 310 – 18,699 m/s, and it can also retroactively measure the speed of sound in objects with known thickness. Gain 0–60 dB, supports both automatic and manual adjustment, and supports TDG (Time-Dependent Gain). Resolution 0.1, 0.01, 0.001, and 0.0001 millimeters are available for selection. Probe frequency range 1 MHz–75 MHz Sampling frequency 40 MHz–500 MHz Working language Chinese and English optional Measurement unit Millimeters, inches, micrometers, mils, meters per second, inches per microsecond, microseconds, nanoseconds Measurement update rate 8Hz, 16Hz, 30Hz, 60Hz, MAX available Turn off the instrument. Optional automatic shutdown after 10, 20, or 30 minutes of inactivity, or manual shutdown. Operating temperature -10°C to 50°C Storage temperature -20°C to 70°C Relative humidity 20% RH to 90% RH External dimensions 264mm × 359mm × 85mm (H × W × D) Weight 5.145kg Working power supply Powered by a 15V 2.6A DC adapter, with a battery life of 150 minutes. Display screen 13-inch touchscreen with a screen resolution of 2880x1920. Rectification Mode RF, Phase-Inverted RF, Full Wave, Positive Half Wave, Negative Half Wave View Mode A-scan, A-scan + B-scan, Interactive Inspection Template Storage 512GB SSD; files can be imported and exported via USB flash drive.